7001 Lark Lane
Sanford, NC 27332
(919) 777-1777

Local Reviews
for oak ridge, nc

Rated 5.0 out of 5 stars based on 6 customer reviews

Great service from company

I was extremely impressed with the professionalism of our tech, and dispatcher! For the first time ever with a contractor, the dispatch called hr into our 4 hr window to let us know they would be there closer to the end of our window, and had 3 folks in front of us. Time being money, it allowed me to not just sit and wait half the day for someone! When our tech arrived he was professional and knowledgeable, and really made you feel like he was taking care of his own house!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for oak ridge, nc

Carl T.

Carl T. Job Checkin

Goodman A/C replaced evap coil and cycled system working at this time


Carl T.

Carl T. Job Checkin

Carrier A/C checked system found compressor and CFM not running due to bad dual run capacitor and replaced with truck stock capacitor and cycled system working at this time


Carl T.

Carl T. Job Checkin

Goodman AtC with case coil checked system found to be low in refrigerate and preferred leak search and found leaking case coil need to replace coil


Carl T.

Carl T. Job Checkin

Goodman Heat pump checked system found compressor not running due to bad windings need to replace compressor


Carl T.

Carl T. Job Checkin

Goodman A/C replaced compressor amd found restricted case coil need to replace case coil


Carl T.

Carl T. Job Checkin

Comfortmaker A/C checked system found bad CFM not to replace condenser fan motor


Carl T.

Carl T. Job Checkin

Trane air hanlder checked system found blower motor not running due to being bad need to replace blower motor


Carl T.

Carl T. Job Checkin

Goodman Heat pump checked system found bad dual run capacitor and replaced with truck stock capacitor and cycled system working at this time


Tony M.

Tony M. Job Checkin

Lennox no blown 45/5 capacitor


Manuel M.

Manuel M. Job Checkin

Incomplete 3 Systems worked on Main Floor Unit and Basement Unit. Main Floor System, Goodman Straight A/C: HO stated system was not cooling. Found Drain line stopped up. Replaced P trap and cleared line. Found system charge low. Added 1 lbs of R22. System is running great at this time. Basement Goodman Straight A/C, M#: GSC130181AE. S#: 0706039509. Case Coil Data: M#: CAPF1824A6AA. S#: 0706598348. HO stated system was not cooling. Found breaker tripped. Checked comp windings. They are bad. Comp needs to be replaced. Called Arco to get part info. P#: AR16. Price: $278.48. In Stock. System holds 7 lbs of R22. Did not order due to HO requesting info towards a new system.


Carl T.

Carl T. Job Checkin

Goodman heat pump repaired leak on suction line and recharged system with 8 lb R-410 refrigerate and cycled system working at this time


Carl T.

Carl T. Job Checkin

Goodman heat pump checked system found to be completely out of refrigerate and preferred leak search and found leak om suction line need to repair leak and recharged system with 8 lb R-410 refrigerate


bradley m.

bradley m. Job Checkin

Complete: 2 systems worked On US Goodman str8 AC. HO said unit was making loud noise outside. Found compressor making loud noise. Checked refrigerant, cap and amp draws and all were good. The issue is just loud noise. Spoke with HO and they were understanding that AHS doesn’t cover noise. System is working as it should at this time.


Carl T.

Carl T. Job Checkin

ICP A/C checked system found to be less then 30 pis refrigerate pressures and preferred leak search and found leaking evap coil need ro replace evap coil


Carl T.

Carl T. Job Checkin

Comfortmaker heat pump checked system found wiring issue amd corrected and cycled system working at this time